Convert TIA .ser and .emi files to TIFF (Beta)

Open FEI TIA .ser files with their .emi without TIA and get calibrated TIFFs, pictures with a scale bar and spectra as CSV.

Opens: EMD (Velox), EMD (Berkeley), DM3, DM4, SER/EMI, SEM TIFF, BCF, SPX, H5OINA, SPD/SPC, JEOL ASW/IMG/MAP/PTS, MRC, MIB, ELID, MSA
Saves: PNG, JPEG, TIFF (ImageJ), CSV, EMD (HDF5), TXT, JSON

Convert

Microscope files
Choose files… or drop them here
.emd, .dm3, .dm4, .ser, .emi, .tif, .tiff, .txt, .hdr, .bmp, .jpg, .jpeg, .png, .bcf, .spx, .h5oina, .h5, .hdf5, .spd, .lsd, .spc, .ipr, .asw, .img, .map, .pts, .eds, .mrc, .mrcs, .mib, .elid, .msa, .ems, .emsa, .zip · up to 4096 MB each, 200 files max
    Add more files

    Velox or Berkeley .emd, .dm3/.dm4, TIA .emi with its .ser files, SEM/TEM .tif (with the .txt or .hdr file Hitachi, JEOL and TESCAN save next to it), Bruker .bcf/.spx, AZtec .h5oina, EDAX .spd with .spc/.ipr, JEOL .asw/.img/.map/.pts/.eds, .mrc, .mib, Phenom .elid or .msa. Several files or a .zip of a folder are converted together.

    Options
    Picture format

    PNG keeps every grey level; JPEG files are smaller.

    Where the scale bar is drawn. Its length is a round number (200 nm, 2 µm, 5 1/nm for diffraction) chosen from the pixel size in the file.

    Automatic picks white or black from the brightness behind the bar.

    Scale bar size

    Removes the strip with the instrument settings at the bottom of SEM pictures (Thermo Fisher/FEI, TESCAN, Zeiss, Hitachi, JEOL) before the scale bar is added. The calibrated TIFF is cut the same way.

    Automatic stretches the grey levels between the 0.5 % darkest and brightest pixels (8-bit pictures stay as recorded; diffraction patterns use a log scale). The TIFF always keeps the original values.

    For drift-corrected frames, image series and STEM scans with several frames. The TIFF always holds every frame.

    For EDS spectrum images: element symbols separated by commas, for example Fe, Ni, O. A line can be named (Au M, Cu L). Leave empty to use the elements stored in the file.

    More options

    Averages neighbouring pixels in the element map pictures so sparse X-ray counts read as areas. The TIFF and CSV files keep the unsmoothed counts.

    A fixed length such as 500 nm, 2 µm or 5 1/nm. Leave empty for an automatic round length.

    For pictures without a calibration, for example 2.5 nm or 0.31 µm per pixel.

    ImageJ-compatible keeps 8-bit and 16-bit data as they are and stores everything else as 32-bit float.

    Also save the whole spectrum image (every pixel's spectrum, as y, x, energy) as a Berkeley EMD (HDF5) file for ncempy, HyperSpy or your own scripts, when it is under 1.5 GB.

    Your files are deleted after processing.

    On FEI Tecnai, Titan and Talos microscopes run with TIA (TEM Imaging and Analysis), each acquisition is saved as a pair: an .emi file with the microscope settings and one or more .ser files with the data, named name_1.ser, name_2.ser and so on, one per detector. This page reads the pair and writes TIFF, PNG and CSV files that any program opens.

    How to convert SER and EMI to TIFF

    1. Upload the .emi file together with all of its .ser files, or a .zip of the folder. The files are matched by name.
    2. Choose the picture format, the scale bar position and colour, and how series are handled (average, first frame, or every frame).
    3. Download a calibrated TIFF and a picture with a scale bar for every detector, plus the settings as text and JSON.

    What is converted

    • Images from the CCD or the STEM detectors, with the pixel size from the .ser file. STEM scans with BF, DF and HAADF give one picture per detector.
    • Image series (previews, tilt or time series) as one multi-page TIFF.
    • Diffraction patterns, calibrated in 1/nm and shown on a log scale.
    • EDS spectra, line scans and spectrum images: CSV with the energy axis, one column per position for line scans, and for spectrum images the sum spectrum, a total-counts map, element maps for the elements you type and the data cube.
    • Settings from the .emi file: high tension, magnification, camera length, mode, spot size, dwell time, stage position and the full description TIA stores.

    Things to watch

    • A .ser file uploaded without its .emi is still converted with its own calibration, but the microscope settings are missing, and a diffraction pattern is then treated as an image. Upload both.
    • TIA stores images bottom-up; the converter flips them so the pictures look as they did on the TIA screen.
    • A spectrum image whose scan was stopped early is converted; the positions that were never scanned stay empty and a note tells you how many hold spectra.

    For DigitalMicrograph files from the same microscopes see DM3 and DM4 to TIFF. Newer Thermo Fisher instruments save .emd: see Velox EMD to TIFF.

    More about what this tool reads and writes: Electron Microscopy File Converter (EMD, DM3, DM4, SER, TIFF).