Convert Shimadzu GC .gcd and GC-MS .qgd files to CSV (Beta)

Get the detector signals, GC traces and peak tables of GCsolution .gcd files and every scan of GCMSsolution .qgd files as CSV and Excel.

Opens: CH, UV, MS, .D (ZIP), DX, LCD, GCD, QGD, .raw (ZIP), CDF
Saves: CSV, XLSX

Convert

Chromatography data
Choose files… or drop them here
up to 200 MB each, 50 files max
    Add more files

    Agilent .ch, .uv or .ms files or a .D folder packed as .zip (ChemStation, OpenLab or MassHunter), an OpenLab CDS .dx file, Shimadzu .lcd, .gcd or .qgd files, a Waters .raw folder packed as .zip, or AIA / ANDI .cdf files. Several files or runs are converted together.

    Options

    Pick the comma version if your Excel uses a decimal comma (most of Europe).

    Chromatograms to extract from diode-array spectra, e.g. 254, 280. Empty: the wavelengths of the file's own signals, else 210, 230, 254 and 280 nm.

    More options

    Absorbance is averaged over wavelength ± half this width, like a DAD signal setting “Sig=254,4”. 0 takes the nearest stored wavelength.

    Your files are deleted after processing.

    Shimadzu GC systems save every injection as a .gcd file (GCsolution and LabSolutions GC), and GC-MS systems as a .qgd file (GCMSsolution). Both are compound documents that only Shimadzu's own software opens, and their text export has to be run file by file on the instrument PC. This page reads them directly.

    How to convert .gcd and .qgd files

    1. Upload one or more .gcd or .qgd files, or a ZIP of a whole folder of them.
    2. Choose the number format: decimal point with commas between columns, or decimal comma with semicolons for Excel in most European languages.
    3. Download the CSV files or the Excel workbook with a chart per signal.

    What you get from a .gcd file

    • Detector signals such as a flame ionization detector, as a CSV with retention time in minutes and the response in µV, with the channel name such as DET#1 (SFID1). The values are the stored numbers themselves; GC files keep them as plain floating-point values.
    • Peak tables as GCsolution stored them: R.Time, start and end, area, height, A/H, mark, ID and compound name, concentration, plates, tailing and resolution.
    • GC traces where the file logs them: column oven and injector temperature, carrier gas pressure and flow, column flow and linear velocity.
    • Sample information: sample name and ID, operator, vial, injection volume, acquisition time, method, batch file, instrument and software version.

    What you get from a .qgd file

    • The total ion chromatogram as GCMSsolution stored it, with the base peak of every scan.
    • Every scan as a long table of scan number, time, m/z and intensity, ready for a pivot table or a script.
    • Sample information: sample name and ID, operator, data file, method and tuning file paths, acquisition time and GCMSsolution version.

    How the numbers were checked

    A GCsolution ASCII export of a GC-2014 run matches all 66,255 chromatogram points and every cell of its 83-peak table. In .qgd files GCMSsolution stores the TIC separately from the scans; for every scan of the files we tested, the intensities we read add up to exactly that TIC, and the strongest ions of a dichloromethane blank come out at m/z 49, 84 and 86 as they should.

    Good to know

    More about what this tool reads and writes: Chromatography Data Converter (Agilent, Shimadzu, Waters, AIA).